As the ions enter the water, the conductivity of the water is increased. That means that less voltage is required to bridge the gap at the controlled constant current. If the current is constantly keyed to conductivity, as the conductivity increases, the voltage drops to keep the current constant. I designed my unit to monitor this voltage drop and shut itself off when it reached the point experimentation and lab tests showed to be the most stable at the highest concentration.